CBRSP - 30A,C RADIATOR ANTI-RUST

  • MSDS: CBRSP
  • Manufacturer: SILOO
  • Product Name: 30A,C RADIATOR ANTI-RUST
  • National Stock Number: 6850-00D005508
Product Identification

Product ID:30A,C RADIATOR ANTI-RUST
MSDS Date:09/01/1989
FSC:6850
NIIN:00D005508
MSDS Number: CBRSP

Responsible Party
SILOO
WARMINSTER, PA 18974
US

Emergency Phone: 215-674-4300

Info Phone: 215-674-4300

Preparer: A. B. REED

Cage: SILOO

Contractor
SILOO
2549 WARMINSTER, PA 18974 US

Telephone: 215-674-4300

Cage: SILOO

Ingredients

HEXANE (N-HEXANE) (CERCLA)

CAS: 110-54-3

RTECS: MN9275000

Fraction By Weight: 34%

OSHA PEL 500 PPM

ACGIH TLV: 50 PPM; 9596

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


TOLUENE (SARA 313) (CERCLA)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 16%

OSHA PEL 200 PPM; Z-2

ACGIH TLV: S, 50 PPM; 9596

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ASPHALT (PETROLEUM)

CAS: 8052-42-4

RTECS: CI9900000

Fraction By Weight: 8%

ACGIH TLV: 5 MG/M3; (FUME);9596


HYDROCARBON RESIN

Fraction By Weight: 24%


PROPANE, FUNCTIONS AS PROPELLANT FOR THIS AEROSOL PACKAGE.

CAS: 74-98-6

RTECS: TX2275000

Fraction By Weight: 18%

OSHA PEL 1000 PPM

ACGIH TLV: ASPHYXIANT; 9596

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL OF MIST MAY CAUSE
BREATHING PROBLEMS. SKIN CONTACT MAY CASUE DRYNESS.
CHRONIC:DERMATITIS.
Explanation of Carcinogenicity:PER MSDS:CHEMICAL LISTED AS CARCINOGEN
OR POTENTIAL CARCINOGEN:NTP/IARC/OSHA:NO.
Effects of Overexposure:BREATHING PROBLEMS. DRY SKIN. DERMATITIS.

First Aid

First Aid:IF SYMPTOMS PERSIST CALL PHYSICIAN. INHAL:REMOVE PERSON TO
FRESH AIR.APPLY ARATIFICIAL RESPIRATION IF NEEDED. EYE:FLUSH
W/WATER. SKIN:WASH EXPOSED AREA W/SOAP/WATER. INGEST:DO NOT INDUCE
VOMIT.CALL PH YSICIAN.

Fire Fighting

Flash Point:NA
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:NONE SPECIFIED BY MANUFACTURER. HMIS:USE
APPROPRIATE FIRE EXTINGUISHING MEDIA FOR SURROUNDING FIRE/MATLS.
Fire Fighting Procedures:IF RESIDUE IGNITES TREAT AS OIL FIRE.
Unusual Fire/Explosion Hazard:IF RESIDUE IGNITES TREAT AS OIL FIRE.

Accidental Release

Spill Release Procedures:VENTILATE AREA. DIKE AREA & ABSORB W/SAND OR
OTHER ABSORBANT.SCRAPE UP & PLACE IN DRUMS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN COOL DRY AREA.
Other Precautions:KEEP CONTAINERS CLOSED WHEN NOT IN USE.

Exposure Controls

Respiratory Protection:MASK TO ELIMINATE MIST IF NEEDED.
Ventilation:IF MISTING OCCURS VENTILATE TO KEEP MIST BELOW TLV.
Protective Gloves:NO GLOVES.
Eye Protection:SAFETY GOGGLES.
Other Protective Equipment:NOT NEEDED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER. HMIS:WASH HANDS
AFTER HANDLING.
Supplemental Safety and Health

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:NA
Decomp Temp:Decomp Text:NP
Vapor Pres:NA
Vapor Density:NA
Spec Gravity:0.9592
pH:NP
Evaporation Rate & Reference:NA
Solubility in Water:MISCIBLE
Appearance and Odor:A WHITE TO OFF-WHITE EMULSION.
Percent Volatiles by Volume:55
Corrosion Rate:NP

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER. HMIS:AVOID
ALL IGN SOURCES.
Hazardous Decomposition Products:CARBON MONOXIDE (FIRE).

Disposal

Waste Disposal Methods:COMPLY W/FED/STATE/LOC REGULATIONS FOR OIL
WASTE. CHEMS FOUND IN SEC 313 OF EPCRA SARA TITLE III & SUBJ TO
RELEASE INVENTORY REPORTING:NONE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.